Catheterization Without Supination-A Series of 36 Prone Position Internal Jugular Vein Cannulations
Description
CONCLUSIONS: In the largest series to date, cannulation of the internal jugular vein with the patient in prone position is feasible but associated with a 6% risk of pneumothorax. Severity of illness in patients intolerant of supine positioning